Ro Plant & Bottling Plant Manufacturers in Nepal
DESIGN PARAMTERS
- FEED FLOW : 2000 LPH
- PERMEATE FLOW : 1200 LPH
- MAXIMUM INLET TDS : 1500 ppm
- PERMEATE TDS : < 25 ppm
- RECOVERY : 95 %
- INLET PRESSURE : 3.0 Kgs/cm2
- HP MOTOR RATING : 2.0 HP [2.18 Kw]
- POWER : 1-Phase, 220 V AC
SCOPE OF SUPPLY
- CARTRIDGE FILTER [5 Micron] : 1 No.
- RO MEMBRANES : 40*40 ( CSM/VONTRON)
- NO. OF MEMBRANES : 4 ( vontron)
- MEMBRANE HOUSING : 2 ( Stainless Steel)
- NO. OF HOUSING : 2
- HIGH PRESSURE PUMP [SS 304] : One (CRI/LUBI)
- PRESSURE GAUGES [0-5 & 0-20] : One Each
- SKID [MS] : One
- ROF INDICATOR : Two
- CONDUCTIVITY INDICATOR [0-200 μs] : One
- INTERCONNECTING PIPEWORK : One Lot UPVC
- LP SWITCH [PVC] : One
- FRP Vessel 13-54 (Pentair make)
- Tds ,meter online : 1 (Digital HM)
- Frame : 1.5 Inces Stainless Steel
- 16.Raw Water Pump: 1 HP (USHA/CRI)