Details of 10000 LPH RO Plant
AQUAFILTER RO SYSTEMS
TECHNICAL DETAILS
Designed Raw Water Analysis
- Total Dissolved Solids : 1500 ppm [Max]
- TREATED WATER PARAMETERS [EX-RO PLANT]
- TDS mg/l : < 75 ppm
- pH : 5.5 – 6.5
- LIMITING CONDITIONS OF THE PLANT:
- OXIDISING ELEMENTS : NIL
- IRON : NIL
- OIL & GREASE : NIL
- WATER SOURCE : BOREWELL
- pH : 4 – 11
- CHLORINE : NIL
- SDI : 3 (Max)
- DESIGN PARAMTERS
- FEED FLOW : 20000 LPH
- PERMEATE FLOW : 10000 LPH
- MAXIMUM INLET TDS : 1500 ppm
- PERMEATE TDS : < 25 ppm
- RECOVERY : 95 %
- INLET PRESSURE : 3.0 Kgs/cm2
- HP MOTOR RATING : 5.0 HP [8.18 Kw]
- POWER : 1-Phase, 220 V AC
- 10000 Lph Ro Plant Description
- Features Technology : Membrane Based, (Size: 8040)
- Electricity : 6KW/440v
- Filtration : Suspended Solids, Chemical Impurities, micro organisms like Cryptosporidium, bacteria genus, and Pathogens e-coli. Pre Filtration : Sand Filter, C Filter, micrometer Filter-5 &10
- Post Filtration : Ozonator / UV (Optinal) Design to figure: TDS up to 4000 ppm, Hardness a thousand mg/I Operating Mode: Automatic + Manual 10000 Lph Ro Plant